Quality
Every lifting lot is proof-tested at 2.5 × WLL. Breaking samples are pulled by heat. Elongation is recorded. The certificate that travels with the crate is the same record we keep in the lab book.
Inspectors can visit. If you send a third-party (SGS, BV, or your own), we schedule against the heat, not against a showroom coil.
References we quote to
- EN 818-2 Grade 80 / Grade 100
- NACM 2010 Grade 70 transport chain
- CE marking where the directive applies
- ISO 9001 quality system at the works
Working load limits assume a competent rigger, the correct included angle, and inspection before each lift. We print that on the tag because that is how the chain is used.
With the shipment
Documents you can file
- Mill certificate per heat
- Proof-test record
- Packing list with crate marks
- Optional PMI / salt-spray for 316
- Optional third-party report